FGC-1070 Gas Chromatograph
Scope
Determination (drinks) volatile organic compounds, blood alcohol content detection, detection of indoor air pollutants (TVOC), flavor liquor composition analysis, transformer oil analysis, testing, high-purity gas analysis of residual solvents in pharmaceuticals, medical devices remaining in Determination of ethylene oxide.
Chromatograph units are mainly used: liquor factory, other wineries, petrochemical, gas liquefaction plant, the coal industry, environmental testing, inspection station, Forensic Center, the public security system, food plants, quality inspection departments, water plants, pharmaceutical plants, detection of pesticide plants, gas plants, chemical plants, packaging plant, paint factory, honey factory, chemical engineering universities and other trace ingredients are required to use gas chromatography, liquid chromatography.
Features
1, The instrument uses Internet communication technologies can be easily composed LAN; Internet for long-distance data transmission, remote control, remote diagnostics, the program can be automatically upgraded.
2, all computerized key operation, 5.7-inch large-screen 13-line LCD display English, man-machine dialogue, easy to operate.
3, a new integrated digital electronic circuits, high control precision, stable and reliable performance, temperature control accuracy of up to 0.1.
4, the unique design solution inlet injector discrimination;-post compensation not only solve the baseline drift caused by temperature programming, and subtracting the background noise, you can get a lower minimum detection limits.
Large oven volume: 300 * 280 * 180 can accommodate two 80m capillary column.
5, better insulation: oven, vaporization, when the test were 300 degrees, the hottest spot outside the box and cover only 40 degrees, improve test speed, security of human safety.
6, the unique design of the vaporization chamber, smaller dead; replacement parts: septum, liner, extreme polarization, and the collector nozzle can replace with one hand; body replacement: packed column, capillary injector, TCD , FID detector requires only a wrench can be completely disassembled, maintenance is very convenient.
7, intelligent opened the door and out of the system infinitely variable air volume, reducing the program up / cool down after the system is stable equilibrium time.
8, which can install two injection systems: packed column capillary split / splitless injection system (having a membrane cleaning function); can also install two identical or different detectors: a FID, TCD, ECD, FPD detection device. Optional automatic / manual six-way gas sampling valve injector, headspace sampler, thermal desorption injector, the injector cracking furnace, methane reformer.
9, start with a powerful and comprehensive self-diagnostic function, visual display fault information, power storage protection, keyboard lock and power supply with anti-interference function mutation.
Technical Parameters
1, temperature range: room temperature ~ 450 ℃, Increment 1 ℃, Accuracy ± 0.1 ℃
2, temperature program: heating rate of 16 bands 0.1 ~ 80 ℃ / min
3, communication interfaces: Ethernet, IEEE802.3
4, the host size: 510 * 500 * 540 (mm)
FGC-1070 Detector main technical indicators